Logo der Universität Wien

Equipment

  • Ultrafast Ti: Sapphire high-power chirped pulse oscillator (based on a FEMTOSOURCE SCIENTIFIC XL; FEMTOLASERS Produktions GmbH) with an 18 W pump laser (Coherent Verdi V-18). Average output power 2.7 W, pulse energy 245 nJ, pulse duration 60 fs, central wavelength 800 nm, bandwidth 25 nm, repetition rate 11 MHz
  • Scanning-near-field nanomanipulation and nanospectroscopy by apertureless 60fs-SNOM under electrochemical surface control
  • Laser microscope (custom-design-based on Axio Imager.M1; Zeiss). High numerical aperture focusing optics.
  • Pump-probe microscope setup (based on AxioImager M1, Zeiss)
  • 60fs-pulse shaping
  • Frequency/power control (FPC) unit (Pockels cell-based). Arbitrary pulse picking up to 10 kHz
  • Autocorrelator
  • Frequency resolved optical gating (FROG)
  • Scanning force microscope (SFM) for dry, inert gas, vacuum, liquid and electrochemical investigations (Aura EC; NTEGRA).
  • Multi-photon laser microscopy (60fs-MHz-high-power-technology)
  • Multi-photon fluorescence laser microscopy (60fs-MHz-high-power-technology)
  • 5ns-high-power laser system (1064nm, 532 nm; Quantel Brilliant-EaZy; pulse frequency 10 Hz, 330 mJ/1064 nm, 165 mJ/532 nm)
  • 7ns-high-power laser system (Quanta-Ray GCR; pulse frequency 20 Hz, 60 mJ/532 nm)
  • FT-IR-spectrometer und microscope (spectro-electrochemistry): fast scan (40 spectra/sec), step scan, electrochemical in-situ equipment, DRIFT, ATR (Bruker VERTEX 70)
  • Electrochemical quartz-microbalance (EQMB) (CHI 440)
  • Scanning Electrochemical Microscope (CHI 920D)
  • Electrochemical impedance spectroscopy and bi-potentiostat (CHI760C)
  • Rotating Disk Electrode (RDE) und Rotating Ring Disk Electrode (RRDE) (Pine Research Instrumentation, AFMSRXE Modulated Speed Rotator;2 RSE 93, A. Jaissle Elektronik Labor / Stuttgart)
  • 3D-Optical Microscopy (AxioImager M1, Zeiss). Camera (AxioCam MRc5; Zeiss). Software Z-scans and 3D deconvolution (AxioVision, Zeiss), fluorescence setup.
  • Custom laser control software (LabVIEW). Control and synchronization of laser energy adjustment, focusing, Pockels cell, and microscope.
  • BRUKER IFS-66 FTIR Spectrometer with Step-Scan Option
  • BRUKER IFS-25 FTIR Spectrometer
  • Inhouse Cluster: Login server, file server (9TB) and cluster based on infiniband connected nodes; 3 Queues (8x2 Xeon X5650, 15x2 Xeon X5550 and 25 quadcore nodes)
  • Project based usage of the Vienna Scienticic Cluster VSC

 

 

 

 

 

Institut für Physikalische Chemie
Universität Wien

Währinger Straße 42
1090 Wien
T: +43-1-4277-524 01
F: +43-1-4277-524 97
E-Mail
University of Vienna | Universitätsring 1 | 1010 Vienna | T +43-1-4277-0